Purpose
Uploads a scenario attachment to the Insight server, reading it from the Mosel working directory.
Synopsis
procedure insightputscenattach(filename:text, overwrite:boolean)
procedure insightputscenattach(filename:text)
Arguments
filename 
The filename of the attachment to be uploaded
overwrite 
If true, will overwrite attachment if it already exists. If false and attachment already exists, will fail with insightattachstatus INSIGHT_ATTACH_ALREADY_EXISTS. Defaults to true if not given.
Example
insightputscenattach('myattach.dat',false)
if insightattachstatus=INSIGHT_ATTACH_OK then
  writeln("Attachment added ok")
elif insightattachstatus=INSIGHT_ATTACH_ALREADY_EXISTS then
  writeln("Attachment already exists")
else
  writeln("Error adding attachment")
end-if
Example of taking a file myattach.dat in the working directory, and saving it as a new scenario attachment called myattach.dat.
Further information
1. Check the attachment status code using insightattachstatus to determine whether the attachment was successfully added.
2. The new attachment will not be available on the Insight server until the scenario completes.
3. Attempting to access attachments when the model is not being run through Xpress Insight will cause the model to abort with an error.
Related topics

© 2001-2019 Fair Isaac Corporation. All rights reserved. This documentation is the property of Fair Isaac Corporation (“FICO”). Receipt or possession of this documentation does not convey rights to disclose, reproduce, make derivative works, use, or allow others to use it except solely for internal evaluation purposes to determine whether to purchase a license to the software described in this documentation, or as otherwise set forth in a written software license agreement between you and FICO (or a FICO affiliate). Use of this documentation and the software described in it must conform strictly to the foregoing permitted uses, and no other use is permitted.