Initializing help system before first use

General errors

These errors may occur either during compilation or when running a model.

E-1   Internal error in `location' (errortype)

An unrecoverable error has been detected, Mosel exits. Please contact Xpress Support.

E-2   General error in `location' (errortype)

An internal error has been detected but Mosel can recover. Please contact Xpress Support.

E-4   Not enough memory

Your system has not enough memory available to compile or execute a Mosel model.

E-21   I cannot open file `file' for writing (driver_error)

Likely causes are an incorrect access path or write-protected files.

E-22   I cannot open file `file' for reading (driver_error)

Likely causes are an incorrect access path or filename or not read-enabled files.

E-23   Error when writing to the file `file' (driver_error)

The file could be opened for writing but an error occurred during writing (e.g. disk full).

E-24   Error when reading from the file `file' (driver_error)

The file could be opened for reading but an error occurred while reading it.

E-25   Unfinished string

A string is not terminated, or different types of quotes are used to indicate start and end of a string.

Example:

 writeln("mytext)

E-26   Identifier expected

May occur when reading data files: a label is missing or a numerical value has been found where a string is expected.

Example:

 declarations
  D: range
 end-declarations

 initializations from "test.dat"
  D
 end-initializations
Contents of test.dat:
 [1 2 3]
The label D: is missing.

E-27   Number expected

May occur when reading data files: another data type has been found where a numerical value is expected.

Example:

 declarations
  C: set of real
 end-declarations

 initializations from "test.dat"
  C
 end-initializations
Contents of test.dat:
 C: [1 2 c]
c is not a number.

E-28   Digit expected for constant exponent

May occur when using scientific notation for real values.

Example:

b:= 2E -10
E must be immediately followed by a signed integer ( i.e. no spaces).

E-29   Wrong file descriptor number for selection (num)

fselect is used with an incorrect parameter value.

E-34   I cannot find IO driver `driver'

The system cannot locate the IO driver driver for opening a file. This may happen if the driver is provided by a module not already loaded in memory. To avoid this problem the module name should be given with the driver name. For instance use "mmodbc.odbc" instead of "odbc" alone.

E-35   Error when closing file `file' (driver_error)

An error occurred while closing a file. Typically the last write operation for clearing buffers failed.

E-36   Read error (file)

I/O error during file reading.

E-37   Invalid character

Invalid character sequence found while reading a text file, non-conforming to the current encoding. Possibly an incorrect encoding (Mosel default is UTF-8) has been specified for accessing this file.

E-38   Unknown compiler flag(s) `flag' ignored

Some of the flag(s) used with compile have not been recognized, please refer to the list documented for compile.

E-39   Unknown BIM reader flag(s) `flag' ignored

Some of the flag(s) used with load have not been recognized, please refer to the list documented for load.

E-40   Unsupported encoding `encoding' (ignored)

The encoding name specified after the marker !@encoding is unknown.


© 2001-2022 Fair Isaac Corporation. All rights reserved. This documentation is the property of Fair Isaac Corporation (“FICO”). Receipt or possession of this documentation does not convey rights to disclose, reproduce, make derivative works, use, or allow others to use it except solely for internal evaluation purposes to determine whether to purchase a license to the software described in this documentation, or as otherwise set forth in a written software license agreement between you and FICO (or a FICO affiliate). Use of this documentation and the software described in it must conform strictly to the foregoing permitted uses, and no other use is permitted.